Should you need to reinstall for any reason, we recommend that you install the latest version. Here are the steps to clean your machine and install the latest version.
+
The most common reason for doing a Clean Reinstallation is to migrate the application to another server. This procedure can also be used to eliminate the currently installed application and install a new, fresh copy in its place.
  
 +
#It is recommended that you update to the latest version prior to reinstallation. If you have a faulty installation that you are going to be replacing, the update can be done later.
 
#Navigate to C:\Program Files\AuditWizard v8\db\.
 
#Navigate to C:\Program Files\AuditWizard v8\db\.
#Copy the file ''aw_db.sdf'' elsewhere as a backup. This is your database file. ''Omit this step if you are starting with a blank database''.
+
#Copy the file ''aw_db.sdf'' elsewhere as a backup. This is your database file. ''Omit this step if you are going to start with a blank database''.
 
#If you have a ''Documents'' folder in C:\Program Files\AuditWizard v8\, copy it elsewhere as a backup.
 
#If you have a ''Documents'' folder in C:\Program Files\AuditWizard v8\, copy it elsewhere as a backup.
#Uninstall AuditWizard in the Programs and Features control panel.
+
#Open the Programs and Features Windows control panel.
 +
#You may have an entry for both AuditWizard and an AuditWizard update. Uninstall any update first, then AuditWizard.
 
#Navigate to C:\Program Files\. If it exists, delete the ''AuditWizard v8'' folder.
 
#Navigate to C:\Program Files\. If it exists, delete the ''AuditWizard v8'' folder.
#Delete the contents of your network share (but not the share itself).
+
#Delete the contents of your '''[[AuditWizard™ - Getting Started - Pre-Installation - Network Share|network share]]''' (but not the share itself).
 
#Navigate to C:\Documents and Settings\All Users\
 
#Navigate to C:\Documents and Settings\All Users\
 
#Delete any shortcut to AuditWizard and enclosing folder.
 
#Delete any shortcut to AuditWizard and enclosing folder.
#Download '''[http://www.laytontechnology.com/trialsoftware/AuditWizard_v8.msi the full installer]'''. This is a trial that can be registered.
+
#Download '''[http://www.laytontechnology.com/trialsoftware/AuditWizard_v8.msi the full installer]'''. This is a trial that can be registered. Note that it may not be the latest version.
 
#Install per the steps in '''[[AuditWizard™ - Getting Started - Installation|Installation]]'''.
 
#Install per the steps in '''[[AuditWizard™ - Getting Started - Installation|Installation]]'''.
#Navigate to C:\Program Files\AuditWizard v8\db\. Replace ''aw_db.sdf'' with your backup. ''Omit this step if you are starting with a blank database''.
+
#Navigate to C:\Program Files\AuditWizard v8\db\. Replace ''aw_db.sdf'' with your backup. ''Omit this step if you are going to start with a blank database''.
 
#If you backed up the ''Documents'' folder, restore it to C:\Program Files\AuditWizard v8\.
 
#If you backed up the ''Documents'' folder, restore it to C:\Program Files\AuditWizard v8\.
 
#Launch. Register on launch. Cancel the Setup Wizard.
 
#Launch. Register on launch. Cancel the Setup Wizard.
 
#Go to '''[[AuditWizard™ - Using AuditWizard - Administration - Auditing - AuditScanner Configuration|Administration > Auditing > AuditScanner Configuration]]'''. Enter the network share path and make any desired changes. Click the ''Save Configuration'' and ''Deploy to Network'' buttons.
 
#Go to '''[[AuditWizard™ - Using AuditWizard - Administration - Auditing - AuditScanner Configuration|Administration > Auditing > AuditScanner Configuration]]'''. Enter the network share path and make any desired changes. Click the ''Save Configuration'' and ''Deploy to Network'' buttons.
#Go to '''[[AuditWizard™ - Using AuditWizard - Administration - Auditing - AuditAgent Configuration|Administration > Auditing > AuditAgent Configuration]]'''. Enter the network share path and make any desired changes. Click the ''Save Configuration'' button.
+
#If you are using the Agent, go to '''[[AuditWizard™ - Using AuditWizard - Administration - Auditing - AuditAgent Configuration|Administration > Auditing > AuditAgent Configuration]]'''. Enter the network share path and make any desired changes. Click the ''Save Configuration'' button.
 
#Go to '''[[AuditWizard™ - Using AuditWizard - Administration - General - AuditWizard Services|Administration > General > AuditWizard Services]]''' and configure your AuditWizard Service.
 
#Go to '''[[AuditWizard™ - Using AuditWizard - Administration - General - AuditWizard Services|Administration > General > AuditWizard Services]]''' and configure your AuditWizard Service.
 
#Do a full network discovery.
 
#Do a full network discovery.
#In Network View, right-click a range of computers and select AuditWizard Agent > Check Status.
+
#If you are using the Agent, in Network View, right-click a range of computers and select ''AuditWizard Agent > Check Status''.
 
#Remove the Agent from any computers to which it has been deployed.
 
#Remove the Agent from any computers to which it has been deployed.
 
#Deploy the Agent again to install the latest version of the Agent service.
 
#Deploy the Agent again to install the latest version of the Agent service.
#Repeat steps 18-20 until all computers running Agents have been updated with the latest Agent.
+
#Repeat steps 20-22 until all computers running Agents have been updated with the latest Agent.
 
<p align="right">[[File:btn_back_up.png|link=AuditWizard™ - Clean Reinstallation]] [[AuditWizard™ - Clean Reinstallation|<u>Back</u>]]</p>
 
<p align="right">[[File:btn_back_up.png|link=AuditWizard™ - Clean Reinstallation]] [[AuditWizard™ - Clean Reinstallation|<u>Back</u>]]</p>

Revision as of 00:38, 15 October 2014

Btn back up.png Back

The most common reason for doing a Clean Reinstallation is to migrate the application to another server. This procedure can also be used to eliminate the currently installed application and install a new, fresh copy in its place.

  1. It is recommended that you update to the latest version prior to reinstallation. If you have a faulty installation that you are going to be replacing, the update can be done later.
  2. Navigate to C:\Program Files\AuditWizard v8\db\.
  3. Copy the file aw_db.sdf elsewhere as a backup. This is your database file. Omit this step if you are going to start with a blank database.
  4. If you have a Documents folder in C:\Program Files\AuditWizard v8\, copy it elsewhere as a backup.
  5. Open the Programs and Features Windows control panel.
  6. You may have an entry for both AuditWizard and an AuditWizard update. Uninstall any update first, then AuditWizard.
  7. Navigate to C:\Program Files\. If it exists, delete the AuditWizard v8 folder.
  8. Delete the contents of your network share (but not the share itself).
  9. Navigate to C:\Documents and Settings\All Users\
  10. Delete any shortcut to AuditWizard and enclosing folder.
  11. Download the full installer. This is a trial that can be registered. Note that it may not be the latest version.
  12. Install per the steps in Installation.
  13. Navigate to C:\Program Files\AuditWizard v8\db\. Replace aw_db.sdf with your backup. Omit this step if you are going to start with a blank database.
  14. If you backed up the Documents folder, restore it to C:\Program Files\AuditWizard v8\.
  15. Launch. Register on launch. Cancel the Setup Wizard.
  16. Go to Administration > Auditing > AuditScanner Configuration. Enter the network share path and make any desired changes. Click the Save Configuration and Deploy to Network buttons.
  17. If you are using the Agent, go to Administration > Auditing > AuditAgent Configuration. Enter the network share path and make any desired changes. Click the Save Configuration button.
  18. Go to Administration > General > AuditWizard Services and configure your AuditWizard Service.
  19. Do a full network discovery.
  20. If you are using the Agent, in Network View, right-click a range of computers and select AuditWizard Agent > Check Status.
  21. Remove the Agent from any computers to which it has been deployed.
  22. Deploy the Agent again to install the latest version of the Agent service.
  23. Repeat steps 20-22 until all computers running Agents have been updated with the latest Agent.